Electrochemical cells
Flow Cell for Screen-Printed Electrodes
FLWCL
Methacrylate wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets Fittings included.
Flow Cell in Teflon for Screen-Printed Electrodes
FLWCL-TEF
Teflon wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets. Fittings included.
Flow Cell in PEEK for Screen-Printed Electrodes
FLWCL-PEEK
PEEK wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets. Fittings included.
Flow Cell in Polypropylene for Screen-Printed Electrodes
FLWCL-P
Polypropylene wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets. Fittings included.
Flow Cell with screws for Screen-Printed Electrodes
FLWCL-SC
Methacrylate (top part) wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with screws. Fittings included.
Did you know?
We share our application expertise in more than 2000 Application Notes, Bulletins and White Papers
Show another
Flow Cell for Interdigitated Electrodes
FLWCL-IDE
Methacrylate wall-jet Flow-Cell for FIA. Suitable to be used with IDE electrodes ref. G-IDEAU10, G-IDEAU5,G-IDEPT10, G-IDEPT5, G-IDECONAU10 and G-IDECONPT10. Closing system with powerful magnets. Fittings included.
Flow Cell in Teflon for Interdigitated Electrodes
FLWCL-IDE-TEF
Teflon wall-jet Flow-Cell for FIA. Suitable to be used with IDE electrodes ref. G-IDEAU10, G-IDEAU5, G-IDEPT10, G-IDEPT5, G-IDECONAU10 and G-IDECONPT10. Closing system with powerful magnets. Fittings included.
Flow Cell for Work in Solution Screen-Printed Electrodes
FLWCL-WS
Methacrylate wall-jet Flow-Cell for FIA. Suitable to be used with work in solution format Screen-Printed Electrodes with the electrochemical cell at the end of the strip. Closing system with powerful magnets. Fittings included.
Flow Cell - Only Working Electrode
CFLWCL-WE
Methacrylate wall-jet Flow-Cell for FIA.Its o-ring entraps only the working electrode. Suitable to be used with standard Screen-Printed Electrodes with the electrochemical cell in the center of the strip. Closing system with powerful magnets. Fittings included.
Flow Cell in Teflon - Only Working Electrode
CFLWCL-WE-TEF
Teflon wall-jet Flow-Cell for FIA.Its o-ring entraps only the working electrode. Suitable to be used with standard Screen-Printed Electrodes with the electrochemical cell in the center of the strip. Closing system with powerful magnets. Fittings included.
Flow Cell for magnetic assays with Screen-Printed Electrodes
CFLWCL-MAGN
Methacrylate wall-jet Flow-Cell associated with a powered magnet designed to do FIA with magnetic beads. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Fittings included.
Flow Cell for 8X format Screen-Printed Electrodes
FLWCL8X
Methacrylate wall-jet Flow-Cell for performing simultaneus measuements in FIA. Suitable to be used with 8X format Screen-Printed Electrodes. Closing system with screws. Fittings included.
Flow Cell for 8X format Screen-Printed Electrodes 1 Channel
FLWCL8X1C
Methacrylate thin-layer Flow-Cell for performing simultaneus measuements in FIA. Suitable to be used with 8X format Screen-Printed Electrodes. Closing system with screws. Fittings included.
Cell for Screen-Printed Electrodes - Conical Well
CFLWCL-CONIC
Methacrylate conic cell suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets.
Cell in Teflon for Screen-Printed Electrodes - Conical Well
CFLWCL-CONIC-TEF
Teflon conic cell suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets.
HPLC Cell for Screen-Printed Electrodes
HPLCELL
Cell in PEEK designed for working in High-Performance Liquid Chromatography systems. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip.
Cell for Screen-Printed Electrodes
CELL
Cell in methacrylatel for batch analysis which allows optional stirring and it's recommended for deaerated samples and for standard additions mode. Suitable for working with all catalogue Screen-Printed Electrodes but recommended to be used with work in solution format SPEs.
Thermostatic Cell for Screen-Printed Electrodes
TCELL
Methacrylate Cell designed to perform batch analysis allowing temperature control through a thermostatic jacket. Suitable for working with all catalogue Screen-Printed Electrodes but recommended to be used with work in solution format SPEs.
Transmission Cell for Transparent Screen-Printed Electrodes
TRANSCELL
Cell in Teflon suitable to perform transmission experiments with transparent Screen-Printed Electrodes in combination with a collimator lens (ref. CLENS).
Reflection Cell for Screen-Printed Electrodes
REFLECELL
Cell in Teflon suitable to perform reflection experiments with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets.
Batch Injection Analysis Cell for Screen-Printed Electrodes (Micropipette P200M)
BIASPE02
Batch Injection Analysis (BIA) cell made in ABS designed to obtain reproducible flow rate and electronically control the injection volume with a programmable electronic micropipette of 20-200 µL. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets.
Batch Injection Analysis Cell for Screen-Printed Electrodes (Micropipette P1000M) in ABS
BIASPE10
Batch Injection Analysis (BIA) cell made in ABS designed to obtain reproducible flow rate and electronically control the injection volume with a programmable electronic micropipette of 100-1000 µL. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets.
Raman Cell for Screen-Printed Electrodes
RAMANCELL
Black teflon reflection cell for performing Raman Spectroelectrochemistry with screen-printed electrodes in combination with ref. RAMANPROBE.
Spectroelectrochemical Reflection Cell for Thin-Layer Flow-Cell Screen-Printed Electrodes
TLFCL-REFLECELL
Cell for performing spectroelectrochemical measurements in flow conditions in combination with the TLFCL-CIR format Screen-Printed Electrodes, the suitable fittings and ref. RPROBE-VIS-UV.
Cell for Screen-Printed Electrodes in PEEK
CELL-PEEK
Cell in PEEK for batch analysis which allows optional stirring and it's recommended for deaerated samples and for standard additions mode. Suitable for working with all catalogue Screen-Printed Electrodes but recommended to be used with work in solution format SPEs.
Optical fiber spectro-electrochemical flow cell setup
001RDX
This is a horizontally mounted, multi-purpose spectroelectrochemical cell designed to be coupled with light sources and spectrometers (UV-Vis, NIR, IR) via optical fibers. It enables obtaining electrochemical and spectroscopic information from liquid sample or thin films in systems where variations in applied potential induce changes in observed spectra.Applied collimating lenses are curved optical lenses that enables parallel irradiation of the sample. Each lens is 5 mm in diameter, has focal length of 10 mm and wavelength range of 200-2000 nm. The cell consists of a polyether ether ketone (PEEK) flow chamber equipped with magnetic mount sample holder (a screw version is available on request), screw mount quartz window holder and two different mini tripods.The cell is meant to be used with standard reference electrode having 6 mm in diameter and counter electrode either in the form of a rod or helix with 6 mm in diameter and 15 mm active length.Please note: this product is not available from Metrohm Germany.
Gas Diffusion Electrode X-Ray diffraction electrochemical flow cell setup
002RDX
This is a horizontally mounted, multi-purpose electrochemical cell for Gas Diffusion Electrode (GDE), designed to be used with X-Ray Diffractometry.The cell consists of two individual compartments: the liquid flow chamber and the gas chamber, which are placed on opposing faces of a GDE. Both compartments are held in place by magnetic/screw mount, providing a leakage-free O-Ring seal.The liquid chamber can be filled with an electrolyte using a syringe or an electrolyte can continuously flow through it using an external reservoir and peristaltic pump (reservoir and pump not included).The dry chamber is gas-tight enabling continuous flow of a gas carrier and evacuation of the gas products for sampling using standard analytical instruments such as a residual gas analyzer. Both compartments are made of a polyether ether ketone (PEEK) material. The cell is meant to be used with standard reference electrode having 6 mm in diameter and counter electrode in the form of a rod/helix with 6 mm in diameter and 15 mm active.Please note: this product is not available from Metrohm Germany.
Spectro-electrochemical flow cell setup with reduced optical path
003RDX
This is a horizontally mounted, multi-purpose spectroelectrochemical cell with 4 mm long optical path (i.e. electrolyte thickness) designed to be used with standard UV-Vis or IR spectrometers. It enables obtaining electrochemical and spectroscopic information from liquid sample or thin film in systems where variations in applied potential induce changes in observed spectra.It consists of a polyether ether ketone (PEEK) flow chamber equipped with magnetic mount sample holder (a screw version is available on request), screw mount quartz window holder and two different mini tripods. It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements.Unlike Spectro-EFC 1.75 mL, this cell is meant to be used with pseudo-reference electrode (50 mm long) and counter electrode in the form of a metal wire (90 mm long), both with plug of 6 mm in diameter. Thanks to the application of pseudo-reference electrode, the thickness of an electrolyte is reduced from 12 mm down to 4 mm. Please note: this product is not available from Metrohm Germany.
Photo-electrochemical single-sided cell setup
004RDX
This is a horizontally mounted, single compartment photo-electrochemical cell. This cell allows several approaches to perform measurements in 2- or 3-electrode setups. It is designed to investigate performance of a thin film photo-anode (e.g.nanocrystalline material or conducting polymer) deposited on a rigid or flexible transparent substrate (typically fused quartz glass).The cathode (counter electrode) and reference electrode are mounted in a top casing. The cell elements are made of PEEK. It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight having gas inlet and outlet, which can be used to bubble the solution and evacuate gases from the chamber.Please note: this product is not available from Metrohm Germany.
Small etch cell setup
005RDX
One of the most common application of an electrochemical etching cell is a preparation of Nanocrystalline Porous Silicon Layer on a single crystal Si wafer. It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements.Please note: this product is not available from Metrohm Germany.
Photo-electrochemical H-cell setup
006RDX
This is a horizontally mounted, double compartment photo-electrochemical H-Cell used to simultaneously investigate thin film photo-anodes and cathodes. The cell elements are made of PEEK. It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements.The construction is gas-tight having two separate chambers, each equipped with gas inlet and outlet. This allows bubbling the solution and evacuating gases. Chambers are separated with an ion-exchange membrane (e.g. DuPont’s Nafion® membrane), so the electrochemial products appearing at photo-anode and cathode do not affect the opposite electrode.Please note: this product is not available from Metrohm Germany.
Bulk electrolysis basic cell set up
007RDX
This is a standard bulk electrolysis cell with basic configuration (known also as potentiostatic coulometry cell or controlled potential coulometry cell). The cell consists of three electrodes: working electrode (reticulated glassy carbon electrode), counter electrodes (Platinum wire) and reference electrode (aqueous Ag/AgCl or non-aqueous Ag/AgCl). The working and counter electrode are installed in the same compartment, while the reference electrode is separated by a ceramic frit.Reticulated glassy (vitreous) carbon electrode provides a large surface area to solution volume ratio. Electrode arrangement and possibility to use magnetic stirring ensure very efficient mass transport conditions. The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight.Please note: this product is not available from Metrohm Germany.
Basic electrochemical cell set up
008RDX
This is a stationary solution basic electrochemical cell for measurements of electrodes in a form of:rod/disc (6 mm dia.); thin film deposited on flat substrate (using a wireclip) ; membrane (using a wire clip); The working, counter and reference electrodes are mounted in a top casing either in 2-, or 3-electrode setup. The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous(EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements.The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte.Please note: this product is not available from Metrohm Germany.
Bottom mount electrochemical cell set up
009RDX
This is a stationary solution voltammetry cell for measurements of a thin film deposited on flat substrate. The sample is loaded from the bottom via magnetic (or screw) mount, while counter or/and reference electrodes are mounted in a top casing (either 2-, or 3-electrode setup).The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte. Please note: this product is not available from Metrohm Germany.
Electrolyte-gated transistor bottom mounted electrochemical cell setup
010RDX
This is a stationary solution electrochemical cell designed to measure characteristics of electrolyte-gated (or solution-gated) transistors using liquid or gel electrolyte. Measured transistor sample can be fabricated on a rigid or flexible flat substrate (not included in the setup) with conducting thin film source and drain, and a layer of conducting or semiconducting channel material.The sample is loaded from the bottom via magnetic (or screw) mount, while gate is mounted in a top casing. A reference electrode can also be mounted in the top casing in case it is needed to control the channel/electrolyte interfacial potential or perform an electrochemical pre-treatment on the channel material. Source and drain electrodes can be accessed through cut-outs in a cell bottom casing, using needle probes or toothless crocodile clips.The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte.Please note: this product is not available from Metrohm Germany.
Corrosion cell
011RDX
This is a stationary solution corrosion cell for EIS and conventional electrochemical measurements on: (a) thin metal film deposited on flat substrate(b) metal plate(c) metal mesh(d) metal wire(e) metal ribbonThe sample is installed from the bottom via magnetic (or screw) mount in between two chambers filled with electrolyte. In cases (a) and (b) bottom chamber is unused and stays dry.The counter or/and reference electrodes are mounted in a top casing (either 2-, or 3-electrode setup). The cell elements are constructed with materials that are inert to the sample (glass and PEEK). It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight and can be used when the removal and exclusion of contaminants such as oxygen and water is required by bubbling of an inert gas through the electrolyte.Please note: this product is not available from Metrohm Germany.
Multiport photo-electrochemical single-sided cell setup
012RDX
This is a horizontally mounted, single compartment multiport photo-electrochemical cell. This cell allows several approaches to perform measurements in 2- or 3-electrode setups. It is designed to investigate performance of a thin film photo-anode (e.g. nanocrystalline material or conducting polymer) deposited on a rigid or flexible transparent substrate (typically fused quartz glass).The cathode (counter electrode) and reference electrode are typically mounted in a top lid, while both side lids can be used to mount up to 4 additional electrodes (e.g. pH meter, thermometer, Clark electrode, etc.). The tubing installed in side lids enables aliquot sample collection (liquid) and supply of gaseous and liquid reagents.The gas inlet and outlet in the top lid can be used to bubble the solution and evacuate gases from the chamber. It well fits aqueous (EPDM O-Rings) and )organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight.Please note: this product is not available from Metrohm Germany.
Double-tank etch cell setup
014RDX
This is a horizontally mounted, double-tank cell typically used for anodization of Si-wafers with electrolyte backside contact. It consists of two polyether ether ketone (PEEK)gas-tight chambers each equipped with sapphire wafer serving as window for illumination allowing light-assisted porous Si formation.It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The Si substrate is mounted in between these chambers and sealed with O-rings under magnetic/screw mount. The preparation of a whole porous Si substrate with this cell is possible at one simple etching step, assuring high reproducibility.Please note: this product is not available from Metrohm Germany.
Photo-electrochemical double-sided cell setup
015RDX
This is a horizontally mounted, single compartment photo-electrochemical cell used to simultaneously investigate thin film photo-anodes and (photo-) cathodes. This cell allows several approaches to perform measurements in 2- or 3-electrode setups.It is designed to investigate performance of a thin film photo-anode (e.g. nanocrystalline material or conducting polymer) deposited on a rigid or flexible transparent substrate (typically fused quartz glass). The cathode (counter electrode) is either mounted in a top casing or attached on the other side of the cell as a thin film deposited on rigid or flexible substrate. The reference electrode is mounted in a top casing.The cell elements are made of PEEK. It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. The construction is gas-tight having gas inlet and outlet, which can be used to bubble the solution and evacuate gases from the chamber.Please note: this product is not available from Metrohm Germany.
1 l corrosion cell
CORR.1LCELL.S
The Autolab 1 l corrosion cell is suitable for corrosion measurements according to ASTM standards. The cell has a thermostatic jacket for temperature control and a series of openings for counter electrodes, pH sensor, thermometer, Luggin-Haber capillary and gas purging.The 1 ll corrosion cell has been designed to measure the corrosion properties samples with a diameter ranging from 14.7 mm to 16 mm and a thickness from 0.5 mm up to 4 mm. The exposed surface is 1 cm² and the seals are made out of natural rubber.
Corrosion cell
CORR.CELL.S
The Autolab 400 ml corrosion cell is suitable for corrosion measurements. The cell has a thermostatic jacket for temperature control and a series of openings for counter electrodes, pH sensor, thermometer, Luggin-Haber capillary and gas purging.The 400 ml corrosion cell has been designed to measure the corrosion properties of 14 mm diameter and 1 mm thick flat circular samples immersed in an electrolyte. The exposed surface area is 0.785 cm². The holder is made of Delrin with a Viton seal.
0.250 L Corrosion Cell
CORR250.CELL.S
Complete cell for corrosion measurements, 250 mL.
EQCM complete cell including cover
EQCM.CELL.S
EQCM complete cell including cover
Flat cell
FLAT.CELL.S
The Autolab flat cell is a corrosion cell suitable for measurements on very large flat samples, up to 17 cm² in size. The cell is supplied with a reference electrode, a stainless steel counter electrode and a gas purging tube.
Flat Sample Platform
FLAT.PLATFORM.CMPL.S
Complete Flat sample platform for large, flat samples. Keywords: Corrosion cell, linear polarization, Tafel, corrosion rate, flat samples, salt spray
H-cell for hydrogen permeation experiments
H-CELL
This cell consists of two electrochemical compartments in which hydrogen is produced in the load cell and detected in the oxidation cell. It can be used to evaluate hydrogen uptake, permeability and transport in a variety of metal membranes, among other applications.
Measuring Cell TSC Battery Expanded
RHD.TSCBATT.ADVANCED
The TSC Battery Expanded is a closed measuring cell intended for assembling half or full battery or supercap cells with e.g. active materials and separators. It is also suitable for investigating solid or gel-like samples in contact with metal electrodes in a plat/plate geometry. You have flexibility with cell configuration either two or three electrode measurements can be performed by inserting a microreference electrode from the side. The standard variant contains flat metal electrodes. For current collectors designed for using elemental lithium as electrode material please refer to the extended variant.
Measuring Cell TSC Spectro
RHD.TSCSPECTRO
The TSC Spectro cell is a closed measuring cell intended for performing spectro-electrochemistry experiments. It comes with a platinum gauze electrode located at the focal point of the sensing light beam entering through adjustable side windows. Both two and three electrode measurements can be performed by inserting a microreference electrode from the side. This cell is airtight and thus shielded against atmosphere and can be used with moisture-sensitive samples. Cell Materials in contact with sample: PEEK, Platinum, Glassy Carbon, EPDM, FFKM
Autolab Electrocatalysis RRDE cell
RRDE.CELL.CPL.S
The Autolab RRDE cell is a complete electrochemical cell designed for experiments under forced convection with the Autolab RRDE (or Autolab RDE2). The kit consists of a glass vessel with a volume of 300 mL, fitted with a thermostatic jacket for temperature control. All the parts that can come in contact with the solution can be cleaned in aggressive conditions, making the cell suitable for typical electrocatalysis experiments or sensitive interfacial electrochemistry measurements.