Du er blevet omdirigeret til din lokale version af den anmodede side

In the course of life, each of us learns to trust our gut feelings or our experiences to avoid situations that seem dangerous or risky. You quite literally sense potential dangers with an uneasy feeling. Who hasn’t painfully learned that touching a hot stove top isn’t a good idea? Or who voluntarily goes outside during a tornado?

2020/08/31/pat-advantages-part-3/_2

While humans can rely on their intuition and learned patterns to avoid dangers or use protective strategies, this is far more complicated with electronic systems or machines. All components of a system must be in a permanently safe state. Failures and malfunctions of individual components can have devastating consequences for production processes and the safety of the operators.

An example of this is the Seveso disaster in 1976, in which highly toxic dioxin TCDD escaped as a result of an uncontrolled reaction, and sustainably poisoned flora and fauna. With regard to other major chemical accidents, the European Seveso III Directive then came into force in 2012 to control major accident hazards to prevent major accidents.

Recognize, master, and avoid errors

Process engineering systems that are operated continuously contain countless components that can wear out or fail during their life cycle. However, if the measuring, control, or regulating circuit is affected, failures can cause immense damage. Under no circumstances should humans nor the environment be exposed to any kind of danger. For this reason, the functional safety of the components must be guaranteed, and their risk and hazard potential must be analyzed in detail.

The service life of mechanical components can be evaluated by observing mechanical wear and tear. However, the aging behavior of electronic components is difficult to assess. A unit of measure that makes risk reduction and thus functional safety quantifiable is the so-called «Safety Integrity Level» (SIL). 
 

The following procedure is followed:

  1.   Risk analysis
  2.   Realization of risk reduction
  3.   Evidence that the realized risk reduction corresponds at least to the required risk reduction

 

Risk assessment: A process is considered safe if the current risk has been reduced below the level of the tolerable risk. If safety is ensured by technical measures, one speaks of functional safety.

Significance for process analysis systems

Errors can happen anywhere, and can never be completely excluded. To minimize possible errors, it is therefore necessary to estimate the risk of occurrence and the damage to be expected from it as part of a risk analysis. A distinction must be made here between systematic and random errors.

Systematic errors are potentially avoidable and are caused, for example, by software errors or configuration deficiencies. Accordingly, they already exist during or prior to commissioning.

In contrast, random errors are potentially difficult to avoid because they occur arbitrarily. Nevertheless, the error rate or failure probability can be determined statistically and experimentally.

Random errors usually result from the hardware and occur during operation. Ultimately, systematic errors should be avoided, and random errors should be mastered to ensure trouble-free functionality.

2020/08/31/pat-advantages-part-3/_4
General process analyzer setup

Process analysis systems are the link between manual laboratory analysis and the industrial process. In applications where continuous and fully automatic monitoring of critical parameters is required, process analyzers are indispensable. Due to the different analysis conditions in the laboratory and directly in the process, there are some challenges when transferring the measurement technology from the lab to the process. The decisive factors are the working and environmental conditions (e.g., high temperatures, corrosive atmospheres, moisture, dust, or potentially explosive environments) which the process analyzers have to meet regarding their design, construction materials, and reliability of the components. The analyzer automatically and continuously transmits system and diagnostic data to prevent hardware or software components from failing through preventive measures. This significantly reduces the chance of random errors occurring.

Process analyzers have been specially developed for use in harsh and aggressive industrial environments. The IP66 protected housing is divided into two parts, and consists of separate wet and electronic parts. The electronics part contains all components relevant to control and operate the process analyzer. Modular components like burettes, valves, pumps, sampling systems, titration vessels, and electrodes can be found in the analyzer wet part. Representative samples can thus be taken from the process measuring point several meters away. The analysis procedure, the methods to be used, and method calculations are freely programmable.

A touchscreen with intuitive menu navigation allows easy operation, so that production processes can be optimized at any time. The course of the measurement is graphically represented and documented over the entire determination, so that the analysis process is completely controlled. The measurement results can be generated 24/7 and allow close and fully automatic monitoring of the process. Limits, alarms, or results are reliably transferred to the process control system.

When operating the analyzer, there is a risk that software errors can lead to failures. In order to recognize this with foresight, the system delivers self-diagnostic procedures as soon as it is powered on and also during operation. This includes, e.g., checking pumps and burettes, checking for leaks, or checking the communication between the I/O controller, the human interface, and the respective analysis module.

The central component of a process analyzer is the measurement technique in use. In the case of sensors or electrodes, there are several requirements such as chemical resistance, ease of maintenance, robustness, or precision which they must meet. The safety-related risk arises from the possibility if measurement sensors fail due to aging, or if they become damaged and subsequently deliver incorrect measurement results.

Failure of the electrode, contamination, or damage must be reported immediately. With online analysis systems, the analysis is performed in an external measuring cell. In addition, recurring calibration and conditioning routines are predefined and are performed automatically. The status of the electrode is continuously monitored by the system.

Between measurements, the electrode is immersed in a membrane-friendly storage solution that prevents drying out and at the same time regenerates the swelling layer. The electrode is therefore always ready for use and does not have to be removed from the process for maintenance. This enables reliable process control even under harsh industrial conditions.

Process analyzers must be able to handle samples for analysis over a wide concentration range (from % down to trace levels) without causing carry-over or cross-sensitivity issues. In many cases, different samples from several measuring points are determined in parallel in one system using different analysis techniques. The sample preparation (e.g., filtering, diluting, or wet chemical digestion) must be just as reliable and smooth as the fully automatic transfer of results to the process control system so that a quick response is possible.

Potential dangers for the entire system can be caused by incorrect measurement results. In order to minimize the risk, a detector is used to notify the system of the presence of sample in the vessel. The testing of the initial potential of the analysis or titration curves / color development in photometric measurements are diagnostic data that are continuously recorded and interpreted. Results can be verified by reference analysis or their plausibility can be clarified using standard and check solutions.

Detect errors before they arise

The risk assessment procedures that are carried out in the context of a SIL classification for process engineering plants are ultimately based on mathematical calculations. However, in the 24/7 operation of a plant, random errors can never be completely excluded. Residual risk always remains. Therefore, the importance of preventive maintenance activities is growing immensely in order to avoid hardware and software failures during operation.

A regular check of the process analyzer and its diagnostic data is the basic requirement for permanent, trouble-free operation. With tailor-made maintenance and service concepts, the analyzer is supported by certified service engineers over the entire life cycle. Regular maintenance plans, application support, calibration, or performance certificates, repairs, and original spare parts as well as proper commissioning are just a few examples.

 

Advantages

of preventive maintenance from Metrohm Process Analytics:

  1. Preservation of your investment
  2. Minimized risk of failure
  3. Reliable measurement results
  4. Calculable costs
  5. Original spare parts
  6. Fast repair
  7. Remote Support

In addition, transparent communication between the process control system and the analyzer is also relevant in the context of digitalization. The collection of performance data from the analyzer to assess the state of the control system is only one component. The continuous monitoring of relevant system components enables conclusions to be drawn about any necessary maintenance work, which ideally should be carried out at regular intervals. The question arises as to how the collected data is interpreted and how quickly it is necessary to intervene. Software care packages help to test the software according to the manufacturer’s specifications, to perform data backup and software maintenance.
 

2020/08/31/pat-advantages-part-3/_6

In real emergency situations in which rapid error analysis is required, manufacturers can easily support the operator remotely using remote maintenance solutions. The system availability is increased, expensive failures and downtimes are avoided, and the optimal performance of the analyzer is ensured.

Author
Dreblow

Dr. Kerstin Dreblow

Product Manager Wet Chemical Process Analyzers
Deutsche Metrohm Prozessanalytik (Germany)