- Release of compliant product within 48 hours.
- Detection of microbial contamination between 6 and 30 hours.
Rapid Microbiology
SY-LAB instrumentation and testkits for rapid microbiological testing save time and money and increase the productivity of your microbiology laboratory.
With SY-LAB rapid microbiological systems, the time to results is significantly reduced, allowing for a much faster release of the manufactured products.
- With 64 individual measuring positions and 2 different temperature zones per instrument, BacTrac can perform all tasks that are performed on the classical agar plate.
- BacTrac devices are the only impedance devices that are equipped with the patented high-resolution Impedance Splitting Technology.
- BacTrac technology is a highly accepted and internationally proven technology. It is successfully used in the food and food ingredient industry, in the water industry and in the pharmaceutical and cosmetics industry.
- Results in a few hours
Absence of TMAC, yeasts and pathogens in 24h.
Absence of moulds in 48h.
The higher the contamination, the shorter the detection time.
- Reduced preparation, handling and reading time
No need for serial dilutions in highly contaminated samples.
- Automated calculation of results
The system automatically determines the result of the sample, which is stored in the database, without the need for the user to be present.
- Automated documentation
Generates reports of results based on different user search criteria. Configured for LIMS.
- Verification of equipment with certified material.
- Verification of microbiological parameters using certified reference material (ISO 17025 and 17034).
- Documented verification protocols.
- Confirmation by Molecular Hybridisation of rRNA.
- Salmonella, Listeria monocytogenes, S. aureus, E. coli, Campylobacter, Vibrio parahaemolyticus.
- Butyric spore count in 24 hours.
- Absence of pathogens.
- Microbiological Quality Indicators.
- Absence of pathogens (specific microorganisms) in 1g of sample in 48h.
- Rapid detection of E.coli, S. aureus, P. aeruginosa, C. albicans, B. cepacia and P. gergoviae
- Detection of > 100 cfu/gr fungi in less than 48h
- Absence of false negatives
- Protocol designed for compliance with ISO 17516
- Procedure that can be validated on your products by MicroBios (accredited laboratory)
- Release of compliant product within 48 hours.
- Detection of microbial contamination between 6 and 30 hours.
- Release of compliant product within 48 hours.
- Detection of microbial contamination between 6 and 30 hours.
Real-time pathogen detection
- Detection of microorganisms in less than 24 hours.
- Validated applications (ISO, DIN, AFNOR).
- Detection and confirmation by molecular hybridisation of Salmonella and Listeria in less than 5 hours.
- Counting of quality indicators in less than 18 hours (Total Aerobic Bacteria, Enterobacteriaceae, Coliforms, E.coli, Moulds and Yeasts).
- Confirmation of pathogens by Riboflow molecular hybridisation probes in less than 20 min (E.coli ,S. aureus, Ps. aeruginosa, Salmonella spp, Listeria spp/Listeria monocytogenes, C. albicans, Vibrio parahaemolyticus and Campylobacter).
- Application validation service.
- IQ/OQ/PQ documentation.
- Verification and maintenance service (ENAC)
Download catalogue "BacTrac - Microbiological Multi Monitoring System".
Pathogen confirmation kits by molecular hybridisation
- Detects only replicating, i.e. live cells
- No amplification reaction or purification required
- Specificity comparable to PCR
- Simple extraction protocol
- No purification steps
- Total assay duration less than 30 min
- Protocols in combination with BacTrac / BioTrac for pathogen confirmation
Download catalogue "RiboFlow Biomolecular Pathogen Detection".
Talk to our specialists and find out the best solution for your needs.